Service Data
Water inlet with thermostat
WATER INLET WITH THERMOSTAT - SERVICE DATA
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 8.0 mm (0.315 in.) or more at 95°C (203°F) |
Cooling fan motor
COOLING FAN MOTOR - SERVICE DATA
| No. 1 cooling fan motor | Standard current | 5.6 to 11.A at 20°C (68°F) |
| No. 1 cooling fan motor |
Cooling fan relay
COOLING FAN RELAY - SERVICE DATA
| 3-5 | 10 MΩ or higher |
| 3-5 | Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
Radiator cap (standard judgment criterion)
RADIATOR CAP (STANDARD JUDGMENT CRITERION) - SERVICE DATA
| Standard valve (for brand-new cap) | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17.8 psi) |
| Minimum standard valve (after using cap) | 78.5 kPa (0.8 kgf/cm2 , 11.4 psi) |