Service Data
2UZ-FE CHARGING - SERVICE DATA
| Battery | Maintenance-free | ||
| Voltage | at 20°C (68°F) | 12.5 to 12.9 V | |
| Generator | Rotor coil resistance | at 20°C (68°F) | 2.3 to 2.7 Ω |
| Slip ring diameter | Standard | 14.2 to 14.4 mm (0.559 to 0.567 in.) | |
| Minimum | 14.0 mm (0.551 in.) | ||
| Brush exposed length | Standard | 10.5 mm (0.413 in.) | |
| Minimum | 4.5 mm (0.177 in.) | ||
| Charging circuit | Regulating voltage | 13.2 to 14.8 V | |
| Regulating amperage | without load | 10 A or less | |
| with load | 30 A or more | ||