Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever this DTC is not present | None |
Case 1:
TYPICAL ENABLING CONDITIONS
| Air pump | Operating |
| Air switching valve | Operating |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
Case 2:
TYPICAL ENABLING CONDITIONS
| Air pump | Not operating |
| Air switching valve | Not operating |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |