On-Vehicle Inspection
- INSPECT ABS MOTOR1 RELAY
- Remove the ABS MOTOR1 relay.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE REFERENCE CHARTTester Connection Specified Condition 1-2 Below 1 Ω 3-5 10 kΩ or higher (When battery voltage is not applied between terminals) 3-5 Below 1 Ω (When battery voltage is applied to terminals 1 and 2) If the value is not as specified, replace the ABS MOTOR1 relay.
- INSPECT ABS MOTOR2 RELAY
- Remove the ABS MOTOR2 relay.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE REFERENCE CHARTTester Connection Specified Condition 1-2 Below 1 Ω 3-5 10 kΩ or higher (When battery voltage is not applied between terminals) 3-5 Below 1 Ω (When battery voltage is applied to terminals 1 and 2) If the value is not as specified, replace the ABS MOTOR2 relay.