Park / Neutral Position Switch: Inspection
- INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTShift Position Tester Connection Specified Condition P 2 - 6 and 4 - 5 Below 1 Ω Except P 2 - 6 and 4 - 5 10 kΩ or higher R 2 - 3 Below 1 Ω Except R 2 - 3 10 kΩ or higher N 2 - 9 and 4 - 5 Below 1 Ω Except N 2 - 9 and 4 - 5 10 kΩ or higher D, S, "+" and "-" 2 - 7 Below 1 Ω Except D, S, "+" and "-" 2 - 7 10 kΩ or higher If the resistance value is not as specified, replace the park/neutral position switch assembly.
- Measure the resistance according to the value(s) in the table below.