Fuel Signal (Fuel Injection Signal) 

FAIL-SAFE CHART

Condition Response Recovery
While the engine switch is turned on (IG), fuel injection signal is interrupted for 60 seconds Fuel gauge calibration is performed using average fuel consumption data Normal data is received

Engine Coolant Temperature Receiver Gauge 

FAIL-SAFE CHART

Condition Response Recovery
Engine coolant temperature data is interrupted for 5 seconds The gauge needle indicates below C Engine coolant temperature data is received

Shift Indicator 

FAIL-SAFE CHART

Condition Response Recovery
"P" to "D" data is interrupted for 3 seconds All indicator lights go off Normal data is received
A/T range data is interrupted for 3 seconds, or more than 2 items are received simultaneously All indicator lights go off Normal data is received

ABS, EBD, BA, TRAC, and VSC 

FAIL-SAFE CHART

Condition Response Recovery
ABS & brake data is interrupted for 1 second The warning light comes on Normal data is received

Door 

FAIL-SAFE CHART

Condition Response Recovery
Regular data is interrupted for 10 seconds The data received most recently remains indicated Normal data is received

Driver Side Seat Belt 

FAIL-SAFE CHART

Condition Response Recovery
Driver side seat belt inner belt assembly data is interrupted for 10 seconds The data received most recently remains indicated Normal data is received

Tire Pressure 

FAIL-SAFE CHART

Condition Response Recovery
Tire pressure data is interrupted for 10 seconds The tire pressure indicator light blinks for 60 to 64 seconds, then comes on Normal data is received

Power Steering 

FAIL-SAFE CHART

Condition Response Recovery
EPS data is interrupted for 1 second The indicator light comes on Normal data is received

HEAD*1 or TAIL*2 

FAIL-SAFE CHART

Condition Response Recovery
Regular data is interrupted for 10 seconds The data received most recently remains indicated Normal data is received

Beam 

FAIL-SAFE CHART

Condition Response Recovery
Regular data is interrupted for 10 seconds The indicator light goes off Normal data is received

Airbag 

FAIL-SAFE CHART

Condition Response Recovery
Airbag data is interrupted for 10 seconds or there is a malfunction in the combination meter (meter CPU) The warning light comes on Normal data is received

Meter Illumination 

FAIL-SAFE CHART

Condition Response Recovery
Illumination data is interrupted for 10 seconds or abnormal data is received The display remains in daytime mode Normal data is received

Multi-information Display 

FAIL-SAFE CHART

Condition Response Recovery
Cruise information data is interrupted for 60 seconds The display becomes blank (only measurement units are displayed) Normal data is received