Satellite Switch: Inspection
- INSPECT SATELLITE SWITCH
- Disconnect the J16 connector.
- Measure the resistance according to the value(s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 2 (LSEL) - 5 (E) Satellite switch LH is pressed Below 1 Ω 2 (LSEL) - 5 (E) Satellite switch LH is not pressed 10 kΩ or higher 3 (SET)- 5 (E) Satellite switch ON/OFF is pressed Below 1 Ω 3 (SET) - 5 (E) Satellite switch ON/OFF is not pressed 10 kΩ or higher 4 (RSEL) - 5 (E) Satellite switch RH is pressed Below 1 Ω 4 (RSEL) - 5 (E) Satellite switch RH is not pressed 10 kΩ or higher HINT.
If the value is not as specified, replace the satellite switch (See REMOVAL )