Purge Valve: Installation
- INSTALL NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
HINT:
The No. 1 vacuum switching valve assembly is the purge valve.
- Install the No. 1 vacuum switching valve assembly with the bolt.
Torque: 21 N*m (214 kgf*cm, 15 ft.*lbf)
- Connect the fuel vapor feed hose and No. 2 fuel vapor feed hose to the No 1 vacuum switching valve assembly.
- Connect the No 1 vacuum switching valve assembly connector.
- Install the No. 1 vacuum switching valve assembly with the bolt.
- INSTALL V-BANK COVER SUB-ASSEMBLY (See INSTALLATION )