- INSPECT STARTER RELAY
- Measure the resistance according to the value(s) in the table below
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 3 - 5 When battery voltage is not applied to terminals land 2 10 kΩ or higher 3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω If the resistance is not as specified, replace the relay
- Measure the resistance according to the value(s) in the table below
- INSPECT STARTER CUT RELAY
- Measure the resistance according to the value(s) in the table below
Standard Resistance
RESISTANCE SPECIFICATIONTerminal Connection Condition Specified Condition 3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher 3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω If the resistance is not as specified, replace the relay.
- Measure the resistance according to the value(s) in the table below