On-Vehicle Inspection
- INSPECT FUNCTION OF CAMSHAFT TIMING CONTROL MOTOR
- Connect the Techstream to the DLC3
- Turn the engine switch on (IG) and turn the Techstream ON.
- Start the engine and warm it up.
- Idle the engine
- Enter the following menus: Powertrain / Engine / Active Test / Control the VVT-iE Linear (Bank 1) or Control the VVT-iE Linear (Bank 2).
- Monitor the output angle of the VVT (VVT-iE Aim Angle (Bank 1) and VVT Change Angle (Bank 1) or VVT-iE Aim Angle (Bank 2) and VVT-iE Change Angle (Bank 2)) displayed on the Techstream.
- Perform the Active Test operation with the engine speed at 1500 rpm.
Specified Condition
SPECIFIED CONDITION CHARTActive Test Movement Order Difference between "MD VVT Aim Angle" and "VVT Change Angle" 0 deg → 10 deg → 20 deg → 40 deg → 10 deg → 0 deg → 10 deg → END Within 5 DegFR If the result is not as specified, inspect the camshaft timing control motor assembly and camshaft timing gear assembly