Camshaft Oil Control Valve: Inspection
- INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
- Measure the resistance according to the value(s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 6 9 to 7 9 Ω If the result is not as specified, replace the oil control valve
- Connect a battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve
OK
SPECIFIED CONDITION CHARTCondition Specified Condition Battery positive (+) voltage is applied Valve moves in left arrow direction shown in illustration Battery positive (+) voltage is cut off Valve moves in right arrow direction shown in illustration If the result is not as specified, replace the oil control valve
NOTE: Do not allow foreign matter to contact the oil seal face of the oil control valve (the surface that contacts the cylinder head cover sub-assembly).HINT
If the valve cannot return properly because of foreign matter, a small pressure leak in the advance direction may occur and a DTC may be stored
- Measure the resistance according to the value(s) in the table below