Park / Neutral Position Switch: Inspection
- INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
- Measure the resistance of the switch when the shift lever is moved to each position
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Shift Lever Position Specified Condition 6 (PL) - 2 (RB) P Below 1 Ω 6 (PL) - 2 (RB) Not in P 10 kΩ or higher 1 (RL) - 2 (RB) R Below 1 Ω 1 (RL) - 2 (RB) Not in R 10 kΩ or higher 9 (NL) - 2 (RB) N Below 1 Ω 9 (NL) - 2 (RB) Not in N 10 kΩ or higher 7 (DL) - 2 (RB) D Below 1 Ω 7 (DL) - 2 (RB) Not in D 10 kΩ or higher
- Measure the resistance of the switch when the shift lever is moved to each position