Inspection Procedure

  1. INSPECT FUSE (D MPX-B1, P IG2) 
    1. Remove the D MPX-B1 fuse from the main body ECU.
    2. Remove the P IG2 fuse from the passenger side junction block.
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      STANDARD RESISTANCE TABLE

      Tester Connection Condition Specified Condition
      D MPX-B1 fuse Always Below 1 Ω
      P IG2 fuse

    NG: REPLACE FUSE 

    OK: Go to next step 

  2. CHECK HARNESS AND CONNECTOR (NO. 1 METER ECU - BATTERY AND BODY GROUND) 
    1. Disconnect the L10 ECU connector.
    2. Measure the resistance and voltage according to the value(s) in the table below.

      Standard resistance 

      STANDARD RESISTANCE TABLE

      Tester Connection Condition Specified Condition
      L10-17 (E2) - Body ground Always Below 1 Ω
      L10-18 (ES) - Body ground

      Standard voltage 

      STANDARD VOLTAGE TABLE

      Tester Connection Switch Condition Specified Condition
      L10-14 (IG2) - Body ground Engine switch on (IG) 11 to 14 V
      L10-13 (B) - Body ground Always
      Fig 1: Identifying L10 ECU Connector Terminals
      G04945166Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE NO. 1 METER ECU  (See DISASSEMBLY  )