Data List / Active Test
- READ DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensor, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may by discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus: Body Electrical / (desired system) / Data List /
- Check the values by referring to the table below.
Tilt & Telescopic:
TILT & TELESCOPIC DATA LIST REFERENCETester Display Measurement Item/Range Normal Condition Tilt Position Current tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Telesco Position Current telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Tilt Return Position Memorized tilt return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Telesco Return Position Memorized telescopic return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Tilt Memory Pos 1 Tilt data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Telesco Memory Pos 1 Telescopic data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Tilt Memory Pos 2 Tilt data of memory position 2 / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Telesco Memory Pos 2 Telescopic data of memory position 27 min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Tilt Memory Pos 3 Tilt data of memory position 31 min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Telesco Memory Pos 3 Telescopic data of memory position 3 / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Tilt Up Limit Uppermost tilt position / Not Mem or Mem Not Mem: Position is not memorized Mem: Position is memorized Tilt Up Limit Position Uppermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Tilt Down Limit Lowermost tilt position / Not Mem or Mem Not Mem: Position is not memorized
Mem: Position is memorizedTilt Down Limit Position Lowermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Telesco Short Limit Shortest telescopic position / Not Mem or Mem Not Mem: Position is not memorized
Mem: Position is memorizedTelesco Short Limit Pos Shortest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Telesco Long Limit Longest telescopic position / Not Mem or Mem Not Mem: Position is not memorized
Mem: Position is memorizedTelesco Long Limit Pos Longest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edges) 7000 to 9000 H (28672 to 36864 edges) Tilt Up SW (CAN) Input state of tilt up by manual switch / ON or OFF ON: Tilt up is activated by manual switch
OFF: Tilt up is not activated by manual switchTilt Down SW (CAN) Input state of tilt down by manual switch / ON or OFF ON: Tilt down is activated by manual switch
OFF: Tilt down is not activated by manual switchTelesco Short SW (CAN) Input state of telescopic short by manual switch / ON or OFF ON: Telescopic short is activated by manual switch
OFF: Telescopic short is not activated by manual switchTelesco Long SW (CAN) Input state of telescopic long by manual switch/ON or OFF ON: Telescopic long is activated by manual switch
OFF: Telescopic long is not activated by manual switchS/B Mem 1 Tilt & telescopic memory position 1/Not Mem or Mem Not Mem: Position is not memorized
Mem: Position is memorizedS/B Mem 2 Tilt & telescopic memory position 2/Not Mem or Mem Not Mem: Position is not memorized
Mem: Position is memorizedS/B Mem 3 Tilt & telescopic memory position 3/Not Mem or Mem Not Mem: Position is not memorized
Mem: Position is memorizedT&T Autoaway Function Auto away and return function/ON or OFF ON: Auto away and return function is allowed
OFF: Auto away and return function is restrainedPower Source Voltage Voltage data of power supply / min.: 0 V, max.: 20 V Actual power supply voltage 11 to 14 V Freeze Speed Info Vehicle speed data / 0 km/h (0 mph), max.: 255 km/h (158 mph) Actual vehicle speed IG SW (CAN) Communication state of engine switch / ON or OFF ON: Communication is normal
OFF: Communication is interruptedIGSW Input state of engine switch / ON or OFF ON: Input signal is normal
OFF: Input signal is interruptedKey Code Confirm (CAN) Communication state of key code confirmation signal / ON or OFF ON: Communication is normal
OFF: Communication is interruptedReceive from Meter Communication state of combination meter signal / OK or Interruption OK: Communication is normal
Interruption: Communication is interruptedReceive from Seat ECU Communication state of seat ECU signal / OK or Interruption OK: Communication is normal
Interruption: Communication is interruptedReceive from Combi Communication state of combination switch ECU signal/OK or Interruption OK: Communication is normal
Interruption: Communication is interruptedJ/B Communication state of main body ECU signal / OK or Interruption OK: Communication is normal
Interruption: Communication is interruptedB/B Communication state of optional after parts ECU signal / OK or Interruption OK: Communication is normal
Interruption: Communication is interruptedThe Number of DTCs Number of diagnosis code / min.: 0, max.: 255 Actual number of diagnosis codes Combination Switch:
COMBINATION SWITCH DATA LIST REFERENCETester Display Measurement Item/Range Normal Condition Telesco Short SW Telesco SHORT switch status / OFF or ON OFF: Telescopic short is not activated by manual switch
ON: Telescopic short is activated by manual switchTelesco Long SW Telesco LONG switch status / OFF or ON OFF: Telescopic long is not activated by manual switch
ON: Telescopic long is activated by manual switchTilt Down SW Tilt DOWN switch / OFF or ON OFF: Tilt down is not activated by manual switch
ON: Tilt down is activated by manual switchTilt Up SW Tilt UP switch / OFF or ON OFF: Tilt up is not activated by manual switch
ON: Tilt up is activated by manual switch
- PERFORM ACTIVE TEST
HINT:
Using the Techstream to perform the Active Tests allows relays, VSVs and actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active test early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus: Body Electrical / Tilt & Telescopic / Active Test /
- Check the values by referring to the table below.
Tilt & Telescopic:
TILT & TELESCOPIC ACTIVE TEST REFERENCETester Display Test Part Control Range Tilt Operation Tilt operation Up / Down Telesco Operation Telescopic operation Long / Short