Typical Enabling Conditions
All
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | None |
Condition (A)
TYPICAL ENABLING CONDITIONS
| IAT (Intake air temperature) sensor circuit | Not circuit malfunction |
| Turbine speed sensor circuit | Not circuit malfunction |
| Output speed sensor circuit | Not circuit malfunction |
| Shift solenoid valve SL1 circuit | Not circuit malfunction |
| Shift solenoid valve SL2 circuit | Not circuit malfunction |
| Shift solenoid valve SL3 circuit | Not circuit malfunction |
| Shift solenoid valve SL4 circuit | Not circuit malfunction |
| Shift solenoid valve SL5 circuit | Not circuit malfunction |
| Shift solenoid valve SR circuit | Not circuit malfunction |
| ECT (Engine coolant temperature) sensor circuit | Not circuit malfunction |
| ATF temperature sensor circuit | Not circuit malfunction |
| KCS sensor circuit | Not circuit malfunction |
| ETCS (Electronic throttle control system) | Not system down |
| CAN communication circuit (ECM - TCM) | Not system down |
| Duration time from engine start | 10 min. or more |
| Time after engine start | 10 min. |
| Driving distance after engine start | 0 km (0 miles) or more |
| IAT (12 sec. after engine start) | 10°C (50°F) or more |
| ECT (12 sec. after engine start) | 10°C (50°F) or more |
Condition (B)
TYPICAL ENABLING CONDITIONS
| Duration time from ECT reaching 60°C (140°F) | 10 sec. or more |
| ECT (12 sec. after engine start) | Less than 35°C (95°F) |