Service Data
Reserve tank cap (for inverter)
RESERVE TANK CAP (FOR INVERTER) - SERVICE DATA
| Item | Specified Condition |
|---|---|
| Standard valve (for brand-new cap) | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17 8 psi) |
| Minimum standard valve (for used cap) | 78 5 kPa (0.8 kgf/cm2 , 11.4 psi) |
Relay
TESTER CONNECTION SPECIFIED CONDITION
| Item | Tester Connection | Specified Condition |
|---|---|---|
| IGCT relay Resistance | 3-5 | 10 kΩ or higher (When battery voltage is not applied between terminals 1 and 2) |
| 3-5 | Below 1Ω (When battery voltage is applied between terminals 1 and 2) |