Front Acceleration Sensor: Inspection
- INSPECT ACCELERATION SENSOR ASSEMBLY
- Connect 3 dry batteries of 1 5 V in series.
- Connect terminal 3 (SGB) to the batteries' positive (+) terminal, and terminal 2 (SGG) to the negative (-) terminal
- Measure the voltage according to the value (s) in the table below
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 1 (SGFL) - 2 (SGG) Sensor is stationary Approx. 2.25 V Sensor is tilted Change between approx. 0.9 to 2.3 V HINT:
When the acceleration sensor is tilted, it may output a different value
NOTE:- Do not apply a voltage of more than 6 V.
- Do not drop the acceleration sensor. If it is dropped, replace it with a new one.
If the result is not as specified, replace the sensor.