3UR-FE STARTING SERVICE DATA

Starter assembly Standard current: 190 A or less at 11.5 V
Starter armature assembly Standard commutator diameter: 35.0 mm (1.38 in.)
Minimum commutator diameter: 34.0 mm (1.34 in.)
Standard commutator undercut depth: 0.7 mm (0.0276 in.)
Minimum commutator undercut depth: 0.2 mm (0.00787 in.)
Maximum commutator circle runout: 0.05 mm (0.00197 in.)
Brush Standard brush length: 15.0 mm (0.591 in.)
Minimum brush length: 10.0 mm (0.394 in.)
Starter brush holder assembly Standard spring installed load:
21.5 to 27.5 N (2.2 to 2.8 kgf, 4.8 to 6.2 lbf)
Minimum spring installed load:
12 3 N (1.3 kgf, 2.8 lbf)