DTC P050B Cold Start Ignition Timing Performance: Description
This monitor will run when the engine is started at an engine coolant temperature of -10 to 50°C (14 to 122°F). The DTC will be stored after the engine idles for 13 seconds (2 trip detection logic).
The DTC is designed to monitor the ignition timing at cold start. When the engine is started at an engine coolant temperature of below 50°C (122°F), the ECM checks the ignition timing at engine idling. If the ignition timing advances beyond the specified level within 10 seconds, the ECM interprets this as a malfunction. The MIL is illuminated and a DTC is stored when the malfunction is detected in consecutive driving cycles (2 tip detection logic).
NOTE:
When the cable is disconnected from the negative (-) battery terminal during inspections or repairs, the ISC (Idle Speed Control) learning values are cleared. This DTC cannot be stored with the ISC learning values cleared.
HINT:
The ISC learning is performed when the engine is warmed up and has been idling for 5 minutes.
DTC DETECTION CONDITION CHART
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| P050B | The ignition timing retard is insufficient at cold start (2 trip detection logic). |
|