Pattern Select Switch: Inspection
- REMOVE NO. 1 PATTERN SELECT SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Switch Condition Specified Condition 4 (P) - 3 (E) Pattern select (PWR) switch on Below 1 Ω 4 (P) - 3 (E) Pattern select (PWR) switch off 10 kΩ or higher 2 (2ND) - 3 (E) Pattern select (2ND) switch continuously pressed Below 1 Ω 2 (2ND) - 3 (E) Pattern select (2ND) switch released 10 kΩ or higher If the result is not as specified, replace the No. 1 pattern select switch assembly.