Inspection Procedure
- CHECK HARNESS AND CONNECTOR (BATTERY - TRANSMISSION CONTROL SWITCH)
- Disconnect the transmission control switch connector of shift lock control unit assembly.
- Measure the voltage according to the value (s) in the table below.
Standard voltage
STANDARD VOLTAGE SPECIFICATIONTester Connection Switch Condition Specified Condition 3 - Body ground IG switch ON 11 to 14 V ↑ IG switch OFF Below 1 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (TRANSMISSION@CONTROL SWITCH - BODY GROUND)
- Measure the resistance according to the value (s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Specified Condition 10 - Body ground Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to Next Step
- Measure the resistance according to the value (s) in the table below.
- INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY
- Measure resistance between each terminal of shift lock control unit assembly when the shift lever is moved to each position.
Standard resistance (Check for short)
STANDARD RESISTANCE SPECIFICATIONTester Connection Shift Position Specified Condition 3 - 8 S, "+" and "-" Below 1 Ω ↑ Except S, "+" and "-" 10 kΩ or higher 4 - 10 Press continuously "+" (Up shift) Below 1 Ω ↑ S 10 kΩ or higher 5 - 10 Press continuously (Down shift) Below 1 Ω ↑ S 10 kΩ or higher
NG: REPLACE SHIFT LOCK CONTROL UNIT ASSEMBLY
OK: Go to Next Step
- Measure resistance between each terminal of shift lock control unit assembly when the shift lever is moved to each position.
- CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)
- Connect the transmission control switch connector of shift lock control unit assembly.
- Turn the ignition switch to the ON position, and measure the voltage according to the value (s) in the table below when the shift lever is moved to each position.
Standard voltage
STANDARD VOLTAGE SPECIFICATIONTester Connection Shift Position Specified Condition E6-20 (S) - Body ground S, "+" and "-" 11 to 14 V ↑ Except S, "+" and "-" Below 1 V - Turn the ignition switch off.
- Disconnect the ECM connector.
- Measure the resistance according to the value (s) in the table below when the shift lever is moved to each position.
Standard resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Shift Position Specified Condition E6-6 (SFTU) - Body ground Press continuously "+" (Up shift) Below 1 Ω ↑ S 10 kΩ or higher E6-5 (SFTD) - Body ground Press continuously "-" (Down shift) Below 1 Ω ↑ S 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE