Inspection Procedure
- CHECK WIRE HARNESS (MULTIPLEX NETWORK SWITCH - BATTERY AND BODY GROUND)
- Disconnect the P20 connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION REFERENCE CHARTTester Connection Condition Specified Condition P20-12 (BDR) - Body ground Always 10 to 14 V Standard resistance
TESTER CONNECTION SPECIFIED CONDITION REFERENCE CHARTTester Connection Condition Specified Condition P20-7 (GND) - Body ground Always Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE