RX 400H
HEATED OXYGEN SENSOR HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
| $42 | $90 | Multiply by 0.001 (A) | Maximum sensor heater current | Minimum test limit | Maximum test limit |
THERMOSTAT
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $E1 | $E8 | Multiply by 01 [°C] | ECT sensor output when estimated ECT reached to malfunction criteria | Malfunction criteria | Maximum test limit |
HO2S BANK 1 SENSOR 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $02 | $07 | Multiply by 0.001 (V) | Minimum sensor voltage | Minimum test limit | Maximum test limit |
| $02 | $08 | Multiply by 0.001 (V) | Maximum sensor voltage | Minimum test limit | Maximum test limit |
| $02 | $8F | Multiply by 0.001 (V) | Maximum oxygen storage capacity | 0 | Maximum test limit |
HO2S BANK 2 SENSOR 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $06 | $07 | Multiply by 0.001 (V) | Minimum sensor voltage | Minimum test limit | Maximum test limit |
| $06 | $08 | Multiply by 0.001 (V) | Maximum sensor voltage | Minimum test limit | Maximum test limit |
| $06 | $8F | Multiply by 0.001 (V) | Maximum oxygen storage capacity | 0 | Maximum test limit |
MISFIRE MONITOR - ALL CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65535 |
| $A1 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65535 |
MISFIRE MONITOR - CYLINDER 1
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A2 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65535 |
| $A2 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65535 |
MISFIRE MONITOR - CYLINDER 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A3 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65535 |
| $A3 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65535 |
MISFIRE MONITOR - CYLINDER 3
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A4 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65535 |
| $A4 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65535 |
MISFIRE MONITOR - CYLINDER 4
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A5 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65535 |
| $A5 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 6,535 |
MISFIRE MONITOR - CYLINDER 5
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A6 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65535 |
| $A6 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65535 |
MISFIRE MONITOR - CYLINDER 6
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A7 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65535 |
| $A7 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65535 |
TID $01: CATALYST - USING A/F SENSOR AND HO2
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.0078 (no dimension) | Catalyst deterioration level (bank 1): Determined by waveform of A/F sensor and HO2S |
Malfunction criterion |
| 0 | $01 | Multiply by 0.0078 (no dimension) | Catalyst deterioration level (bank 1): Determined by waveform of A/F sensor and HO2S |
Malfunction criterion for catalyst deterioration |
Bank 1 Sensor 1
A/F SENSOR BANK 1 SENSOR 1
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $01 | $91 | Multiply by 0.003 [mA] | Air-fuel ratio sensor current for bank 1 sensor 1 | Malfunction criterion for low side rationality | Malfunction criterion for high side rationality |
A/F SENSOR BANK 2 SENSOR 1
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $05 | $91 | Multiply by 0.003906 [mA] | A/F current | Minimum Test Limit | Maximum Test Limit |
TID $06: A/F SENSOR
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.000244 (No dimension) | Parameter for identify A/F sensor response rate (bank 1) | Malfunction criterion |
| 0 | $11 | Multiply by 0.000244 (No dimension) | Parameter for identify A/F sensor response rate (bank 2) | Malfunction threshold for A/F sensor deterioration |
EVAP
| MID | TID | Scaling | Description |
|---|---|---|---|
| $3D | $CB | Multiply by 0.001 {kPa} | Test value for vacuum pump OFF stuck (P2401) |
| $CD | Multiply by 0.001 {kPa} | Test value for vacuum pump ON stuck (P2402) | |
| $CE | Multiply by 0.001 {kPa} | Test value for vent valve OFF stuck (P2420) | |
| $CF | Multiply by 0.001 {kPa} | Test value for vent valve ON stuck (P2419) | |
| $D0 | Multiply by 0.001 {kPa} | Test value for reference orifice low-flow (P043E) | |
| $D1 | Multiply by 0.001 {kPa} | Test value for reference orifice high-flow (P043F) | |
| $D4 | Multiply by 0.001 {kPa} | Test value for purge VSV close stuck (P0441) | |
| $D5 | Multiply by 0.001 {kPa} | Test value for purge VSV open stuck (P0441) | |
| $D7 | Multiply by 0.001 {kPa} | Test value for purge flow insufficient (P0441) | |
| $D8 | Multiply by 0.001 {kPa} | Test value for canister small leak (P1420) | |
| $D9 | Multiply by 0.001 {kPa} | Test value for canister gross leak (P1421) | |
| $DA | Multiply by 0.001 {kPa} | Test value for fuel tank small leak (P1422) | |
| $DB | Multiply by 0.001 {kPa} | Test value for fuel tank gross leak (P1423) | |
| $DC | Multiply by 0.001 {kPa} | Test value for fuel vapor-containment valve close stuck (P2451) | |
| $DD | Multiply by 0.001 {kPa} | Test value for fuel vapor-containment valve open stuck (P2450) |