Mass Air Flow Meter: Removal: Removal
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL WARNING:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
- REMOVE COOL AIR INTAKE DUCT SEAL See step 5
- REMOVE ENGINE ROOM SIDE COVER RH See step 7
- REMOVE MASS AIR FLOW METER
- Disconnect the MAF meter connector.
- Remove the 2 screws and MAF meter.
- Remove the O-ring from the MAF meter.