Inspection Procedure
- CHECK GENERATOR ASSEMBLY (TERMINAL B)
- CHECK GENERATOR ASSEMBLY (IG INPUT VOLTAGE)
- Disconnect the E24 generator connector.
- Measure the resistance according to the value (s) in the table below.
Standard voltage
STANDARD VOLTAGE REFERENCE CHARTTester Connection Switch Condition Specified Condition E24-2 (IG) - Body ground Engine switch on (IG) 11 to 14 V NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE PASSENGER SIDE JUNCTION BLOCK (ELECTRIC POWER CONTROL ECU)