On-Vehicle Inspection

  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL 
    CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
    NOTE: After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to record various types of memory and settings. As a result, after turning the engine switch off, wait 6 minutes or more before disconnecting the cable from the negative (-) battery terminal.
  2. REMOVE STARTER RELAY (ST) 
    1. Remove the starter relay from the engine room No. 2 relay block.
  3. INSPECT STARTER RELAY 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE REFERENCE

      Tester Connection Condition Specified Condition
      3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω
      Fig 1: Inspecting Starter Relay (ST)
      G04943935Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      If the resistance is not as specified, replace the relay.

  4. INSTALL STARTER RELAY 
  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL 
  6. PERFORM INITIALIZATION 
    1. Perform initialization (see INITIALIZATION ).