Typical Enabling Conditions
MONITOR STRATEGY
| Monitor runs whenever following DTCs not present | P0102, P0103, P010C, P010D (Mass Air Flow Sensor) P0097, P0098, P0112, P0113 (Intake Air Temperature Sensor) P0115, P0117, P0118 (Engine Coolant Temperature Sensor) P0335, P0337, P0338 (Crankshaft Position Sensor) P0120, P0121, P0122, P0123, P0220, P0222, P0223, P2135 (Throttle Position Sensor) P0452, P0453 (EVAP System) P2401, P2402 (Leak detection pump) P2419, P2420 (EVAP system vent valve) |
| Throttle position (TP sensor voltage) | 0.24 to 3.6 V |
| Time after engine start | 5 seconds or more |
| Battery voltage | 10.5 V or more |
| Engine coolant temperature | 70°C (158°F) or more |
| Estimated load | 30 to 100% |
| IAT sensor circuit | OK |
| ECT sensor circuit | OK |
| CKP sensor circuit | OK |
| TP sensor circuit | OK |
| Canister pressure sensor circuit | OK |
| EVAP leak detection pump | OK |
| EVAP vent valve | OK |