Service Data
POWER SOURCE/WIRING SERVICE DATA
| Battery current sensor | 2 (VC) - 4 (E2) | Resistance: 3 to 10 kΩ at 20°C (68°F) |
| 2 (VC) - 3 (IB) | Resistance: 0.5 kΩ or less at 20°C (68°F) |
|
| 3 (IB) - 4 (E2) | Resistance: 3 to 10 kΩ at 20°C (68°F) |
|
| 1 (THB) - 4 (E2) | Resistance: 1.5 to 2.5 kΩ at 20 to 30°C (68 to 86°F) 0.3 to 6.0 kΩ at 0 to 70°C (32 to 158°F) |