On-Vehicle Inspection (To 10/2008)
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL WARNING:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
- REMOVE IG2 RELAY
- Remove the engine room No. 1 relay block cover.
- Remove the IG2 relay from the engine room No. 1 relay block.
- INSPECT IG2 RELAY
- INSTALL IG2 RELAY
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
- PERFORM INITIALIZATION
- Perform initialization. Refer to INITIALIZATION
.NOTE:
Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.
- Perform initialization. Refer to INITIALIZATION
.