Symptom Suspected Area See
Power window does not operate with power window regulator master switch 1. ECU-B No. 2 fuse -
2. Power window master switch Refer to Power Window Master Switch Power Source Circuit
3. Power window regulator motor Refer to INSPECTION
4. Power window regulator master switch Refer to INSPECTION
Front passenger side power window does not operate with power window regulator switch 1. Power window master switch Refer to INSPECTION
2. Power window regulator motor Refer to INSPECTION - Step 1
3. Power window regulator switch Refer to INSPECTION
Rear LH side power window does not operate with power window regulator switch 1. Power window regulator switch Refer to INSPECTION - Step 2
2. Power window regulator motor Refer to INSPECTION - Step 4
3. Power window regulator switch (rear LH side) Refer to Rear Power Window Switch LH Circuit
Rear RH side power window does not operate with power window regulator switch 1. Power window regulator switch Refer to INSPECTION - Step 1
2. Power window regulator motor Refer to INSPECTION - Step 3
3. Power window regulator switch (rear RH side) Refer to Rear Power Window Switch RH Circuit
AUTO UP/DOWN function does not operate (Only jam protection assistant) 1. Diagnosis check Refer to DIAGNOSIS SYSTEM 
2. Power window regulator motor reset Refer to INITIALIZATION 
3. Power window regulator master switch Refer to INSPECTION
4. Wire harness -
Remote UP/DOWN function does not operate 1. DATA LIST/ACTIVE TEST Refer to DATA LIST / ACTIVE TEST 
2. Power window regulator master switch Refer to INSPECTION
3. Wire harness -
Power window can be operated after engine switch is turned off even if operated conditions are not met 1. Front door courtesy switch Refer to INSPECTION - Step 1
2. Wire harness (LIN communication line) -
AUTO UP operation does not fully close power window (Jam protection function is activated) 1. Power window regulator motor reset Refer to INITIALIZATION 
2. Check & clean glass run -
3. Power window regulator master switch Refer to INSPECTION