| Front speed sensor |
LH |
1 (FL+) - 2 (FL-) |
Always |
1.4 to 1.8 kΩ at 20°C (68°F) |
| 1 (FL+) - Body ground |
Always |
10 kΩ or higher |
| 2 (FL-) - Body ground |
Always |
10 kΩ or higher |
| RH |
1 (FR+) - 2 (FR-) |
Always |
1.4 to 1.8 kΩ at 20°C (68°F) |
| 1 (FR+) - Body ground |
Always |
10 kΩ or higher |
| 2 (FR-) - Body ground |
Always |
10 kΩ or higher |
| Skid control sensor |
LH |
2 (RL+) - 1 (RL-) |
Always |
0.9 to 2.1 kΩ |
| 2 (RL+) - Body ground |
Always |
10 kΩ or higher |
| 1 (RL-) - Body ground |
Always |
10 kΩ or higher |
| RH |
2 (RR+) - 1 (RR-) |
Always |
0.9 to 2.1 kΩ |
| 2 (RR+) - Body ground |
Always |
10 kΩ or higher |
| 1 (RR-) - Body ground |
Always |
10 kΩ or higher |
| VSC NO. 1 (Fail Safe) relay |
- |
Resistance 3 - 5 |
Always |
10 kΩ or higher |
| Resistance 3 - 5 |
Apply B+ between terminals 1 and 2 |
Below 1 Ω |
| VSC NO. 1 relay |
- |
Resistance 3 - 5 |
Always |
10 kΩ or higher |
| Resistance 3 - 5 |
Apply B+ between terminals 1 and 2 |
Below 1 Ω |
| Stop light control relay |
with Dynamic radar cruise control system |
Resistance 3 - 4 |
Always |
Below 1 Ω |
| Resistance 3 - 5 |
Always |
10 kΩ or higher |
| Resistance 3 - 4 |
When battery positive voltage is applied to terminal 1 and battery negative voltage to terminal 2 |
10 kΩ or higher |
| Resistance 3 - 5 |
When battery positive voltage is applied to terminal 1 and battery negative voltage to terminal 2 |
Below 1 Ω |