Power Windows cannot be Operated with All Window Switch: Procedure
- CHECK MANUAL UP / DOWN FUNCTION
- Check that the manual up and down function using the power window regulator master switch assembly and power window regulator switch assembly can operate all the power windows. Refer to OPERATION CHECK .
OK
Manual up and down function is normal.
NG → See step 15
OK: Go to next step
- Check that the manual up and down function using the power window regulator master switch assembly and power window regulator switch assembly can operate all the power windows. Refer to OPERATION CHECK .
- CHECK REMOTE UP / DOWN FUNCTION
- Check that the remote up and down function using the power window regulator master switch assembly operates the power windows. Refer to OPERATION CHECK .
OK
Remote up and down function is normal.
NG → See step 15
OK: Go to next step
- Check that the remote up and down function using the power window regulator master switch assembly operates the power windows. Refer to OPERATION CHECK .
- CHECK ALL POWER WINDOW OPERATION
- Check the operation of the manual function of the all window switch.RESULT
Result Proceed to Only all power window manual operation does not function A Only all power window auto down operation does not function B Both all power window manual operation and auto down operation do not function C
B → See step 11
C → See step 14
A: Go to next step
- Check the operation of the manual function of the all window switch.
- CHECK ALL POWER WINDOW OPERATION (MANUAL OPERATION)
- Check the operation of the manual function of the all window switch.RESULT
Result Proceed to None of the power windows operate with all power window manual up operation A None of the power windows operate with all power window manual down operation B Only driver door window does not operate with all power window manual up operation or all power window auto down operation C Only front passenger door window does not operate with all power window manual up operation or all power window manual down operation D Only one or both of the quarter windows do not operate with all power window manual up operation or all power window manual down operation E
B → See step 8
C → See step 16
D → See step 17
E → See step 18
A: Go to next step
- Check the operation of the manual function of the all window switch.
- READ VALUE USING TECHSTREAM (ALL WINDOW SWITCH (SLIDING ROOF SWITCH ASSEMBLY))
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG)
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Retractable Hardtop / Data List.
- Read the Data List according to the display on the Techstream.RETRACTABLE HARDTOP (SLIDING ROOF CONTROL ECU ASSEMBLY)
Tester Display Measurement Item/Range Normal Condition Diagnostic Note All Windows Up SW/Manual All window switch manual up signal/ON or OFF ON: UP switch pulled up
OFF: UP switch not pulled up- OK
On the Techstream screen, ON or OFF is displayed accordingly.
NG → See step 6
OK → See step 18
- INSPECT ALL WINDOW SWITCH (SLIDING ROOF SWITCH ASSEMBLY)
- Remove the all window switch (sliding roof switch assembly). Refer to REMOVAL .
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
STANDARD RESISTANCETester Connection Switch Condition Specified Condition 7 (UP) - 6 (E) UP switch pulled up Below 50 Ω 7 (UP) - 6 (E) UP switch not pulled up 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(All Window Switch (Sliding Roof Switch Assembly))
NG → See step 19
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (ALL WINDOW SWITCH - SLIDING ROOF CONTROL ECU)
- Disconnect the sliding roof control ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition J109-7 (UP) - Q35-21 (WUP) Always Below 1 Ω J109-7 (UP) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 18
- READ VALUE USING TECHSTREAM (ALL WINDOW SWITCH (SLIDING ROOF SWITCH ASSEMBLY))
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG)
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Retractable Hardtop / Data List.
- Read the Data List according to the display on the Techstream.RETRACTABLE HARDTOP (SLIDING ROOF CONTROL ECU ASSEMBLY)
Tester Display Measurement Item/Range Normal Condition Diagnostic Note All Windows Down SW/Manual All window switch manual down signal/ON or OFF ON: DOWN switch pushed halfway down
OFF: DOWN switch not pushed down- OK
On the Techstream screen, ON or OFF is displayed accordingly.
NG → See step 9
OK → See step 18
- INSPECT ALL WINDOW SWITCH (SLIDING ROOF SWITCH ASSEMBLY)
- Remove the all window switch (sliding roof switch assembly). Refer to REMOVAL .
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
STANDARD RESISTANCETester Connection Switch Condition Specified Condition 8 (DOWN) - 6 (E) DOWN switch pressed halfway down Below 50 Ω 8 (DOWN) - 6 (E) DOWN switch not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(All Window Switch (Sliding Roof Switch Assembly))If the result is not as specified, replace the sliding roof switch assembly.
NG → See step 19
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (ALL WINDOW SWITCH - SLIDING ROOF CONTROL ECU)
- Disconnect the sliding roof control ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition J109-8 (DOWN) - Q35-20 (WDN) Always Below 1 Ω J109-8 (DOWN) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 18
- READ VALUE USING TECHSTREAM (ALL WINDOW SWITCH (SLIDING ROOF SWITCH ASSEMBLY))
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG)
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Retractable Hardtop / Data List.
- Read the Data List according to the display on the Techstream.RETRACTABLE HARDTOP (SLIDING ROOF CONTROL ECU ASSEMBLY)
Tester Display Measurement Item/Range Normal Condition Diagnostic Note All Windows Down SW/Auto All window switch auto down signal/ON or OFF ON: DOWN switch pushed down
OFF: DOWN switch not pushed down- OK
On the Techstream screen, ON or OFF is displayed accordingly.
NG → See step 12
OK → See step 18
- INSPECT ALL WINDOW SWITCH (SLIDING ROOF SWITCH ASSEMBLY)
- Remove the sliding roof switch assembly. Refer to REMOVAL .
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Switch Condition Specified Condition 4 (AUTO) - 6 (E) DOWN switch pressed down Below 50 Ω 4 (AUTO) - 6 (E) DOWN switch not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(All Window Switch (Sliding Roof Switch Assembly))If the result is not as specified, replace the sliding roof switch assembly.
NG → See step 19
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (ALL WINDOW SWITCH - SLIDING ROOF CONTROL ECU)
- Disconnect the sliding roof control ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition J109-4 (AUTO) - P53-23 (WADN) Always Below 1 Ω J109-4 (AUTO) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 18
- CHECK HARNESS AND CONNECTOR (ALL WINDOW SWITCH - BODY GROUND)
- Disconnect the all window switch (sliding roof switch assembly) connector.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition J109-6 (E) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 19
- GO TO OTHER PROBLEM (Proceed to Problem Symptoms Table). Refer to PROBLEM SYMPTOMS TABLE
- REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY. Refer to REMOVAL
- REPLACE POWER WINDOW REGULATOR SWITCH ASSEMBLY. Refer to REMOVAL
- REPLACE SLIDING ROOF CONTROL ECU ASSEMBLY. Refer to REMOVAL
- REPLACE ALL WINDOW SWITCH (SLIDING ROOF SWITCH ASSEMBLY). Refer to REMOVAL