Home >> Lexus >> 2012 >> IS F >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (Diagnostics & Symptom Tests) >> Power Window Control System >> Symptom Tests >> Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch >> Inspection Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Inspection Procedure

NOTE:
  • When the power window regulator motor assembly (for driver side) is reinstalled or replaced, the power window control system must be initialized.
  • After a door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the auto up function is used. In such cases, the auto up function can be reinitialized by repeating the following operations at least 5 times:
    1. Close the power window by fully pulling up the multiplex network master switch assembly and holding it at the auto up position.
    2. Open the power window by fully pushing down the multiplex network master switch assembly.