Purge Flow Monitor
NOTE:
Perform this monitor confirmation after the Key-Off Monitor Confirmation shows Complete.
- Preconditions
The monitor will not run unless:
- The vehicle has been driven at 60 km/h (40 mph) or more for 10 minutes or more.
- The engine coolant temperature is 4.4°C (40°F) or higher.
- The intake air temperature is 4.4°C (40°F) or higher.
- Monitor Conditions
- Release the pressure from the fuel tank by removing and reinstalling the fuel tank cap assembly.
- Warm the engine up until the engine coolant temperature reaches more than 75°C (167°F).
- Increase the engine speed to 3000 rpm once.
- Allow the engine to idle and turn the A/C switch on for 1 minute.
- Monitor Status
- Turn the ignition switch off (if ON or if the engine is running).
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Monitor / Current Monitor.
- Check the Monitor Status displayed on the Techstream.NOTE: If Incomplete is displayed, the monitor did not complete. Make sure that the preconditions have been met, and perform the Monitor Conditions again.