Data List/Active Test
- DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensor, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.- Warm up the engine.
- Turn the engine switch off.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical/Electric Power Control/Data List.
- According to the display on the Techstream, read the "Data List".ELECTRIC POWER CONTROL
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Electrical Charge Current Current battery current value display/
Min.: -300, Max.: 100 [A]Amperage value is displayed - Battery Temperature Current battery temperature value display/
Min.: -30, Max.: 90 [°C]Temperature near battery is displayed - Battery Voltage Current battery voltage value display/
Min.: 0, Max.: 16.67 [V]Battery voltage is displayed - Power Cut Signal Condition of relay (which cuts part of vehicle's power) display/
ON or OFFON: Power supply supplied
OFF: Power supply cut- Battery Voltage Low Battery voltage drop judgment display/
ON or OFFON: Dropped
OFF: NormalMeter display is shown Control Load Level 3 Electrical equipment operation limit display/
ON or OFFON: During electrical equipment operation limit
OFF: No electrical equipment operation limitMeter display is shown Voltage Detection Battery voltage detection path malfunction display/
ON or OFFON: Malfunctioning
OFF: NormalMeter display is shown Alternator Failure Display for generator malfunction or charging line malfunction/
ON or OFFON: Malfunctioning
OFF: NormalMeter display is shown Control Load Level Current load control level display/
0 to 30: No control
1: Load control level 1
3: Load control level 3Load control level 2 is not displayed Request to Limit EPS EPS current consumption limit request display/
0 to 10: No request is made
1: Request is made- Req Limit Air Suspension Air suspension current consumption limit request display/
ON or OFFON: No request is made
OFF: Request is made- Ctrl Load Lv1 History Load control level 1 history count/
0 to 255History count until now - Ctrl Load Lv3 History Load control level 3 history count/
0 to 255History count until now - Req Ctrl Load on Fail Hist Load control operation history display (when charging system is malfunctioning)/
ON or OFFON: Operation history is present
OFF: No operation history- Req Ctrl Load on EPS Hist Load control operation history display (during EPS operation)/
ON or OFFON: Operation history is present
OFF: No operation history- Req Ctrl Load on PCS Hist Load control operation history display (during PCS operation)/
ON or OFFON: Operation history is present
OFF: No operation history- Req Ctrl Load Hist 3 Load control operation history display (when battery voltage is low)/
ON or OFFON: Operation history is present
OFF: No operation history- Req Ctrl Load Hist 2 Load control operation history display (when battery voltage is low)/
ON or OFFON: Operation history is present
OFF: No operation history- Req Ctrl Load Hist 1 Load control operation history display (when battery voltage is low)/
ON or OFFON: Operation history is present
OFF: No operation history- Hist-Bat Vol for Ctrl Load Battery voltage value display (when load control is performed)/
Min.: 0, Max.: 16.67 [V]Battery voltage value when load control is performed is displayed - Hist-Bat Cur for Ctrl Load Battery current value display (when load control is performed)/
Min.: -300, Max.: 100 [A]Battery current value when load control is performed is displayed - Bat Temp Hist Battery temperature value display (when load control is performed)/
Min.: -150, Max.: 150 [°C]Battery temperature value when load control is performed is displayed - Virtual Opn Circuit Vol Hist Battery virtual open-circuit voltage value display (when load control is performed)/
Min.: 0, Max.: 16.67 [V]Battery virtual open-circuit voltage value when load control is performed is displayed - Internal Resistance Hist Battery interior resistance value display (when load control is performed)/
Min.: 0, Max.: 120 [mΩ]Battery interior resistance value when load control is performed is displayed - # Codes Number of trouble code - -
- ACTIVE TEST
HINT:
Using the Techstream to perform the Active Tests allows relays, VSVs and actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
- Warm up the engine.
- Turn the engine switch off.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical/Electric Power Control /Active Test.
- According to the display on the Techstream, perform the "Active Test".ELECTRIC POWER CONTROL
Tester Display Test Part Control Range Activate Power Cut Relay When OFF, power cut linked parts cannot be used ON/OFF Limit Load Level Limit control is performed on heater related load control linked systems 0/1/3 Request to Limit EPS Limit control is performed on current for EPS assist ON/OFF Request to Limit Air Suspension Limit control is performed on air suspension compressor operation ON/OFF