Jam Protection Function does not Operate: Procedure
- PERFORM INITIALIZATION (APPLICABLE LOCATION)
- Initialize the power window regulator motor assembly (applicable location). Refer to INITIALIZATION [08/2012 - ] .
NEXT: Go to next step
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
- Check if the power window auto up and down functions operate normally. Refer to OPERATION CHECK [08/2012 - ]
.
OK
Auto up and down functions are normal.
NG → See step 4
OK: Go to next step
- Check if the power window auto up and down functions operate normally. Refer to OPERATION CHECK [08/2012 - ]
.
- CHECK JAM PROTECTION FUNCTION OPERATING RANGE
- Check if the jam protection function operates normally for the applicable power window.
HINT:
The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.
OK
Jam protection function operates normally.
Result
Result Proceed to OK A NG (Driver door power window) B NG (Front passenger side power window) B NG (Rear LH side power window) C NG (Rear RH side power window) C
B → See step 5
C → See step 6
A → END (PROBLEM DUE TO INITIALIZATION FAILURE)
- Check if the jam protection function operates normally for the applicable power window.
- GO TO OTHER PROBLEM (Proceed to Problem Symptoms Table). Refer to PROBLEM SYMPTOMS TABLE [08/2012 - ]
- REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side or Front Passenger Side). Refer to REMOVAL [08/2012 - ]
- REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Rear LH Side or Rear RH Side). Refer to REMOVAL [08/2012 - ]