LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2013 >> LX 570 >> Repair and Diagnosis (Single Page) >> Body & Frame >> Windows >> Power Window Control System (Diagnostic Codes & Symptom Tests) >> Power Window Control System >> Symptom Tests >> Jam Protection Function does not Operate >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Jam Protection Function does not Operate: Procedure

  1. PERFORM INITIALIZATION 
    1. Initialize the power window regulator motor. Refer to INITIALIZATION [01/2012 - ] .
    2. Check if the power window auto up/down function operates. Refer to OPERATION CHECK [01/2012 - ] .

      OK

      Auto up/down function operates.

    NG → END (PROBLEM DUE TO INITIALIZATION FAILURE) 

    OK: Go to next step 

  2. CHECK JAM PROTECTION FUNCTION OPERATING RANGE 
    1. Check if the jam protection function operates for applicable power window.

      HINT: 

      The jam protection function does not operate from the fully closed position of the door glass to 4 mm (0.157 in.) below that.

      OK

      Jam protection function operates.

      RESULT

      Result Proceed to
      OK A
      NG (Driver side power window) B
      NG (Front passenger side power window) C
      NG (Rear power window LH) D
      NG (Rear power window RH) E

    B → See step   3 

    C → See step   5 

    D → See step   4 

    E → See step   6 

    A → END 

  3. REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to  REMOVAL [01/2012 - ] 
  4. REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to  REMOVAL [01/2012 - ] 
  5. REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH. Refer to  REMOVAL [01/2012 - ] 
  6. REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY RH. Refer to  REMOVAL [01/2012 - ]