LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2015 >> CT 200h Base >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System - Diagnostics - Introduction >> Power Window Control System >> Initialization [08/2014 - 08/2015] >> Initialization [08/2014 - 08/2015]
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Initialization [08/2014 - 08/2015]

  1. INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MOTOR ASSEMBLY (ALL DOORS)) 
    WARNING:

    When a door window regulator assembly, power window regulator motor assembly, door glass or door glass run is reinstalled or replaced, the power window control system must be initialized. Functions such as the auto up and down, jam protection, remote control and key-off operation will not operate if initialization is not performed.

    NOTE:
    • When a power window regulator motor (front door window regulator assembly) is replaced, DTC B2313 is stored. Clear the DTC after initialization.
    • When performing initialization, do not perform any other procedures.
    • When performing initialization, use the power window switch of each door to initialize each door window.
    • If initialization is not completed properly, the LIN communication system may have a malfunction (See article. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2014 - ] ).
    • Make sure to park the vehicle and turn off all the electrical systems before performing initialization. Initialization will be canceled if the vehicle is driven during initialization.
    • Make sure not to hit, strike or vibrate the door window glass during initialization because the vehicle is learning the sliding resistance of the door window glass.
    • Make sure not to operate the power switch to ready on or off during initialization.

    HINT: 

    When the auxiliary battery is replaced, it is not necessary to initialize the power window regulator motor assembly.

    1. Perform initialization according to the table below.
      Condition of Power Window Proceed to
      Initialization method when a power window regulator motor assembly has been replaced with a new one. Procedure A
      Initialization method when a door window regulator assembly has been removed/installed or a door glass and/or door glass run etc. have been removed/installed or replaced with new ones.
      HINT: 
      Use this procedure if the power window regulator motor assemblies have been reused.
      Procedure B
      Initialization method when a reverse rotation malfunction occurs due to a sliding resistance change resulting from adjustment etc. Procedure C
    2. Procedure A
      1. Connect the auxiliary battery and turn the power switch on (IG).
      2. Fully open the window by fully pushing down the switch on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
      3. Fully close the power window by fully pulling up the switch on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position.
    3. Procedure B
      1. Connect the auxiliary battery and turn the power switch on (IG).
      2. Fully close the power window by fully pulling up the switch on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled, release the switch and fully pull it again).
      3. Fully open the window by pushing down the switch on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
      4. Release the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly. Then fully push down and hold the switch for 4 seconds or more.
      5. Fully close the power window by fully pulling up the switch on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.
    4. Procedure C
      1. Connect the auxiliary battery and turn the power switch on (IG).
      2. Fully open the window by fully pushing down the switch on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
      3. Fully close the power window by fully pulling up the switch on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.