Customize Parameters [01/2023 - ]
- CUSTOMIZE PRE-COLLISION SYSTEM NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Customizing with the Multi-information Display
- Turn the engine switch on (IG).
- Select the setting by referring to the table below.
- Using the steering pad switches, change the customize settings.
HINT:
Each item is displayed on the "Setting" tab on the multi-information display.
PRE-COLLISION SYSTEM SETTINGSDisplay Description Setting Default PCS Turns the pre-collision system function on/off. ON/OFF ON Sensitivity Sets the pre-collision system function warning sensitivity Early/Middle/Late Middle
- Customizing with the Techstream
- Select the setting by referring to the table below.
Others
Tester Display Description Default Setting ECU PCS Function ON/OFF State Stored Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 1 Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 2 Refer to the table below Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 3 Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera MEASUREMENT ITEMCustomize Setting Description Setting PCS Function ON/OFF State Stored Function to maintain the pre-collision system on/off setting when the engine switch is turned on (IG) from off. Not stored: Pre-collision system always turns on
Stored: Pre-collision system maintains previous settingPCS Warning Timing State Stored 1 Function to set whether or not to store the warning sensitivity setting when the PCS function is turned from off to on while the engine switch is on (IG). Not stored: Sensitivity setting is reset to Middle
Stored: Sensitivity settings are maintained as previous valuePCS Warning Timing State Stored 2 Function to set whether or not to store the warning sensitivity setting when the PCS function is on and the engine switch is turned from off to on (IG). Not stored: Sensitivity setting is reset to Middle
Stored: Sensitivity settings are maintained as previous valuePCS Warning Timing State Stored 3 Function to set whether or not to store the warning sensitivity setting when the PCS function is off and the engine switch is turned from off to on (IG). Not stored: Sensitivity setting is reset to Middle
Stored: Sensitivity settings are maintained as previous value
- Select the setting by referring to the table below.