Inspection [08/2015 - ]: Procedure
- INSPECT NO. 1 TURBO PRESSURE SENSOR
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 1 Turbo Pressure Sensor)Standard Resistance
Tester Connection Condition Specified Condition 4 (THIM) - 2 (E2) -20°C (-4°F) 13.8 to 18.6 kΩ 20°C (68°F) 2.09 to 2.81 kΩ 80°C (176°F) 0.274 to 0.370 kΩ If the result is not as specified, replace the No. 1 turbo pressure sensor.
- Measure the resistance according to the value(s) in the table below.