Inspection [04/2013 - 10/2017]: Procedure
- INSPECT CRANKSHAFT POSITION SENSOR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Temperature Specified Condition 1 - 2 Cold 1630 to 2740 Ω Hot 2065 to 3225 Ω HINT:
In the table above, the terms "Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122 °F) and "Hot" is from 50 to 100°C (122 to 212°F).
If the resistance is not as specified, replace the crankshaft position sensor.
- Measure the resistance according to the value(s) in the table below.