Installation [04/2013 - 10/2017]: Procedure
- INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Refer to INITIALIZATION [04/2013 - 10/2017]
- Install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.NOTE:
Make sure that the O-ring is not cracked or moved out of place when installing the mass air flow meter sub-assembly.
- Connect the mass air flow meter sub-assembly connector.
- Install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.
- PERFORM INITIALIZATION
- Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Refer to INITIALIZATION [04/2013 - 10/2017]
- Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.