Jam Protection Function does not Operate [09/2015 - ]: Procedure
- PERFORM INITIALIZATION
- Initialize the power window regulator motor assembly.
- Check if the power window AUTO UP/DOWN function operates normally.
OK
AUTO UP/DOWN function operates normally.
Result: NG
NG
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result: OK
OK
See step 2
- CHECK JAM PROTECTION FUNCTION OPERATING RANGE
- Check if the jam protection function operates normally for applicable power window.
HINT:
The jam protection function does not operate between the fully closed position of the door glass and the position 4 mm (0.157 in.) below the fully closed position.
OK
Jam protection function operates normally.
RESULT:Result Proceed to OK A NG (Front LH side power window) B NG (Front RH side power window) C NG (Rear LH side power window) D NG (Rear RH side power window) E
Result: A
A
END
Result: B
B
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
(Refer to REMOVAL [09/2015 - ] )
Result: C
C
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
(Refer to REMOVAL [09/2015 - ] )
Result: D
D
REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
(Refer to REMOVAL [09/2015 - ] )
Result: E
E
REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
(Refer to REMOVAL [09/2015 - ] )
- Check if the jam protection function operates normally for applicable power window.