Installation [09/2014 - 11/2017]: Procedure
- INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Refer to INITIALIZATION [09/2014 - 11/2017]
- Install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.NOTE:
- If the mass air flow meter sub-assembly has been struck or dropped, replace it.
- If reusing the mass air flow meter sub-assembly, be sure to inspect the O-ring.
- Make sure that the O-ring is not cracked or does not move out of place during installation.
- Connect the mass air flow meter sub-assembly connector.
- Install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.
- PERFORM INITIALIZATION
- Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Refer to INITIALIZATION [09/2014 - 11/2017]
- Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.