Installation [08/2015 - ]: Procedure
- INSTALL MASS AIR FLOW METER ASSEMBLY
HINT:
Perform "Inspection After Repairs" after replacing the mass air flow meter assembly (Refer to INITIALIZATION [08/2015 - ] ).
- Install the mass air flow meter assembly with the 2 screws.
Torque: 0.97 N*m (10 kgf*cm, 9 in.*lbf)
- Install the mass air flow meter assembly with the 2 screws.
- INSTALL AIR CLEANER CAP SUB-ASSEMBLY
- Attach the 4 clamps to install the air cleaner cap.TEXT IN ILLUSTRATION
*1 Air Cleaner Cap *2 Air Cleaner Hose *3 Groove *4 Protrusion *a Upper Side *b Front HINT:
When installing the air cleaner hose, align its groove with the protrusion of the throttle body as shown in the illustration.
- Tighten the hose clamp.
Torque: 5.0 N*m (51 kgf*cm, 44 in.*lbf)
HINT:
Make sure the direction of the hose clamp is as shown in the illustration.
- Attach the clamp and connect the mass air flow meter assembly connector.
- Attach the 4 clamps to install the air cleaner cap.