DTC P0604-44: Internal Control Module Random Access Memory (RAM) Error Data Memory Failure [05/2023 - ]: Procedure
- CLEAR DTC
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Clear the DTCs.
Powertrain > Engine > Clear DTCs
- Turn the power switch off.
Result
Proceed to NEXT
Result:
NEXT
See step 2
- READ OUTPUT DTC (DTC P0604-44)
- Disconnect the cable from the negative (-) auxiliary battery terminal and wait for 1 minute.
- Connect the cable to the negative (-) auxiliary battery terminal.
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Wait 16 seconds or more.
- Enter the following menus: Powertrain / Engine / Trouble Codes.
- Read the DTCs.
Powertrain > Engine > Trouble Codes
Result
Result Proceed to DTCs are not output A DTC P0604-44 is output B
Result:
A
CHECK FOR INTERMITTENT PROBLEMS. Refer to CHECK FOR INTERMITTENT PROBLEMS [01/2017 - ]
Result:
B
REPLACE ECM. Refer to REMOVAL [05/2023 - ]