On-Vehicle Inspection [12/2017 - 10/2023]: Procedure
- INSPECT NO. 1 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI-MAIN NO. 1)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 1 electronic fuel injection main relay (EFI-MAIN NO. 1).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 2 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI-MAIN NO. 2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 2 electronic fuel injection main relay (EFI-MAIN NO. 2).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 3 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI-MAIN NO. 3)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 3 electronic fuel injection main relay (EFI-MAIN NO. 3).
- Measure the resistance according to the value(s) in the table below.
- INSPECT ELECTRONIC DRIVER UNIT RELAY (EDU)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the electronic driver unit relay (EDU).
- Measure the resistance according to the value(s) in the table below.
- INSPECT AIR FUEL RATIO SENSOR HEATER RELAY (A/F HTR)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the air fuel ratio sensor heater relay (A/F HTR).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 1 VVT RELAY (VVT NO. 1)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 1 VVT relay (VVT NO. 1).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 2 VVT RELAY (VVT NO. 2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 2 VVT relay (VVT NO. 2).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 2 IGNITION RELAY (IG2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 2 ignition relay (IG).
- Measure the resistance according to the value(s) in the table below.