On-Vehicle Inspection [09/2015 - ]: Procedure
- INSPECT INJECTOR RELAY (INJ)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the injector relay (INJ).
- Measure the resistance according to the value(s) in the table below.
- INSPECT FUEL PUMP RELAY (FUEL PMP)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the fuel pump relay (FUEL PMP).
- Measure the resistance according to the value(s) in the table below.