Motor Generator Control System
MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [01/2023 - 11/2023]
| DTC Code | Description |
|---|---|
| P062F-46 | Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1C | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1F | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent |
| P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P0A00-11 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
| P0A00-15 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
| P0A00-1C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
| P0A1B-00 | Drive Motor "A" Control Module Performance |
| P0A1B-04 | Drive Motor "A" Control Module System Internal Failure |
| P0A1B-1F | Generator Control Module Circuit Intermittent |
| P0A1B-29 | Drive Motor "A" Control Module Signal Invalid |
| P0A1B-47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure |
| P0A1C-00 | Drive Motor "B" Control Module Performance |
| P0A1C-04 | Drive Motor "B" Control Module System Internal Failure |
| P0A1C-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P0A1C-29 | Drive Motor "B" Control Module Signal Invalid |
| P0A1C-47 | Drive Motor "B" Control Module Watchdog / Safety MCU Failure |
| P0A2A-11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A-15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A-1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A-1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A30-11 | Drive Motor "B" Temperature Sensor Circuit Short to Ground |
| P0A30-15 | Drive Motor "B" Temperature Sensor Circuit Short to Battery or Open |
| P0A30-1C | Drive Motor "B" Temperature Sensor Circuit Voltage Out of Range |
| P0A30-1F | Drive Motor "B" Temperature Sensor Circuit Intermittent |
| P0A3F-16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F-1F | Drive Motor "A" Position Sensor Circuit Intermittent |
| P0A3F-21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
| P0A3F-22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
| P0A3F-2B | Drive Motor "A" Position Sensor Signal Cross Coupled |
| P0A45-16 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold |
| P0A45-1F | Drive Motor "B" Position Sensor Circuit Intermittent |
| P0A45-21 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum |
| P0A45-22 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum |
| P0A45-2B | Drive Motor "B" Position Sensor Signal Cross Coupled |
| P0A5D-12 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A5D-14 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A5D-1C | Drive Motor "A" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A5D-1F | Drive Motor "A" Phase U Current (High Resolution) Circuit Intermittent |
| P0A63-12 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A63-14 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A63-1C | Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A63-1F | Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
| P0A66-12 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A66-14 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A66-1C | Drive Motor "B" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A66-1F | Drive Motor "B" Phase U Current (High Resolution) Circuit Intermittent |
| P0A6C-12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A6C-14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A6C-1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A6C-1F | Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent |
| P0A78-72 | Drive Motor "A" Inverter Actuator Stuck Open |
| P0A78-73 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A78-9E | Drive Motor "A" Inverter Stuck On |
| P0A79-72 | Drive Motor "B" Inverter Actuator Stuck Open |
| P0A79-73 | Drive Motor "B" Inverter Actuator Stuck Closed |
| P0A79-9E | Drive Motor "B" Inverter Stuck On |
| P0A90-00 | Drive Motor "A" Performance |
| P0A91-00 | Drive Motor "B" Performance |
| P0AED-11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
| P0AED-15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
| P0AED-1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
| P0AF2-11 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground |
| P0AF2-15 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open |
| P0AF2-1C | Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range |
| P0BE5-12 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
| P0BE5-14 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BE5-28 | Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BE9-12 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
| P0BE9-14 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BE9-28 | Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BED-12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
| P0BED-14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BED-28 | Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BF1-12 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery |
| P0BF1-14 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BF1-28 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF5-12 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery |
| P0BF5-14 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BF5-28 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF9-12 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery |
| P0BF9-14 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BF9-28 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BFD-62 | Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure" |
| P0BFE-62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure |
| P0BFF-1D | Drive Motor "A" Circuit Current Out of Range |
| P0C02-1D | Drive Motor "B" System Circuit Current Out of Range |
| P0C19-00 | Drive Motor "A" Execution Torque Performance |
| P0C1A-00 | Drive Motor "B" Execution Torque Performance |
| P0C50-13 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
| P0C50-16 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C50-17 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C50-1F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
| P0C55-13 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open |
| P0C55-16 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C55-17 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C55-1F | Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5A-13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
| P0C5A-16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5A-17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5A-1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
| P0C5F-13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open |
| P0C5F-16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5F-17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5F-1F | Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent |
| P0C79-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0C7A-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0D2D-16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
| P0D2D-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0D2D-1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
| P0DA3-16 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold |
| P0DA3-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0DA3-1F | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Intermittent |
| P163E-94 | Drive Motor "A" Control Module Monitoring System Unexpected Operation |
| P163F-94 | Drive Motor "B" Control Module Monitoring System Performance Unexpected Operation |
| P19F9-1C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range |
| P1BFA-46 | Internal Control Module (EEPROM Resolver Learning Value) Calibration / Parameter Memory Failure |
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
| P1C2C-1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range |
| P1C5D-19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
| P1C5E-19 | Drive Motor "B" Inverter Circuit Current Above Threshold |
| P1C60-1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
| P1C62-1F | Generator Control Module Offset Power Circuit Intermittent |
| P1C63-1F | Drive Motor "B" Control Module Offset Power Circuit Intermittent |
| P1C65-1F | Generator Control Module Circuit Intermittent |
| P1C66-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P1C67-1F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C68-1F | Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C6A-9F | Motor Shutdown Stuck Off |
| P1C6B-9F | Rear Motor Shutdown Stuck Off |
| P1CAD-49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
| P1CAE-49 | Drive Motor "B" Position Sensor Internal Electronic Failure |
| P1CB0-38 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
| P1CB1-38 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect |
| P1CB6-9E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
| P1CE2-11 | PCU Interlock Circuit Short to Ground |
| P1CE4-9E | Drive Motor "B" Inverter Voltage Sensor "A" Stuck On |
| P1F67-11 | Rear PCU Interlock Circuit Short to Ground |
| P2600-31 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P2600-96 | Coolant Pump "A" Control Circuit Component Internal Failure |
| P26F4-31 | Coolant Pump "C" Control Circuit No Signal |
| P26F4-96 | Coolant Pump "C" Control Circuit Component Internal Failure |
| P274A-11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A-15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A-1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A-1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P275A-11 | Transmission Fluid Temperature Sensor "D" Circuit Short to Ground |
| P275A-15 | Transmission Fluid Temperature Sensor "D" Circuit Short to Battery or Open |
| P275A-1C | Transmission Fluid Temperature Sensor "D" Circuit Voltage Out of Range |
| P275A-1F | Transmission Fluid Temperature Sensor "D" Circuit Intermittent |
| U0293-00 | Lost Communication with Hybrid/EV Powertrain Control Module |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U1150-87 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
| U115E-87 | Lost Communication with Drive Motor Control Module "B" (ch3) Missing Message |
| U1170-00 | Lost Communication with Brake System Control Module (Gear Shift Control Module "A") |
| U1170-08 | Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure |
| U11B3-08 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Bus Signal / Message Failure |
| U11B3-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [11/2023 - ]
| DTC Code | Description |
|---|---|
| P062F-46 | Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1C | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06B3-1F | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent |
| P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P0A00-11 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
| P0A00-15 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
| P0A00-1C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
| P0A1B-00 | Drive Motor "A" Control Module Performance |
| P0A1B-04 | Drive Motor "A" Control Module System Internal Failure |
| P0A1B-1F | Generator Control Module Circuit Intermittent |
| P0A1B-29 | Drive Motor "A" Control Module Signal Invalid |
| P0A1B-47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure |
| P0A1C-00 | Drive Motor "B" Control Module Performance |
| P0A1C-04 | Drive Motor "B" Control Module System Internal Failure |
| P0A1C-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P0A1C-29 | Drive Motor "B" Control Module Signal Invalid |
| P0A1C-47 | Drive Motor "B" Control Module Watchdog / Safety MCU Failure |
| P0A2A-11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A-15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A-1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A-1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A30-11 | Drive Motor "B" Temperature Sensor Circuit Short to Ground |
| P0A30-15 | Drive Motor "B" Temperature Sensor Circuit Short to Battery or Open |
| P0A30-1C | Drive Motor "B" Temperature Sensor Circuit Voltage Out of Range |
| P0A30-1F | Drive Motor "B" Temperature Sensor Circuit Intermittent |
| P0A3F-16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F-1F | Drive Motor "A" Position Sensor Circuit Intermittent |
| P0A3F-21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
| P0A3F-22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
| P0A3F-2B | Drive Motor "A" Position Sensor Signal Cross Coupled |
| P0A45-16 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold |
| P0A45-1F | Drive Motor "B" Position Sensor Circuit Intermittent |
| P0A45-21 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum |
| P0A45-22 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum |
| P0A45-2B | Drive Motor "B" Position Sensor Signal Cross Coupled |
| P0A5D-12 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A5D-14 | Drive Motor "A" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A5D-1C | Drive Motor "A" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A5D-1F | Drive Motor "A" Phase U Current (High Resolution) Circuit Intermittent |
| P0A63-12 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A63-14 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A63-1C | Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A63-1F | Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
| P0A66-12 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Battery |
| P0A66-14 | Drive Motor "B" Phase U Current (High Resolution) Circuit Short to Ground or Open |
| P0A66-1C | Drive Motor "B" Phase U Current (High Resolution) Circuit Voltage Out of Range |
| P0A66-1F | Drive Motor "B" Phase U Current (High Resolution) Circuit Intermittent |
| P0A6C-12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A6C-14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A6C-1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A6C-1F | Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent |
| P0A78-72 | Drive Motor "A" Inverter Actuator Stuck Open |
| P0A78-73 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A78-9E | Drive Motor "A" Inverter Stuck On |
| P0A79-72 | Drive Motor "B" Inverter Actuator Stuck Open |
| P0A79-73 | Drive Motor "B" Inverter Actuator Stuck Closed |
| P0A79-9E | Drive Motor "B" Inverter Stuck On |
| P0A90-00 | Drive Motor "A" Performance |
| P0A91-00 | Drive Motor "B" Performance |
| P0AED-11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
| P0AED-15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
| P0AED-1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
| P0AF2-11 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground |
| P0AF2-15 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open |
| P0AF2-1C | Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range |
| P0BE5-12 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
| P0BE5-14 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BE5-28 | Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BE9-12 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
| P0BE9-14 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BE9-28 | Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BED-12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
| P0BED-14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BED-28 | Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
| P0BF1-12 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery |
| P0BF1-14 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BF1-28 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF5-12 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery |
| P0BF5-14 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BF5-28 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF9-12 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery |
| P0BF9-14 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BF9-28 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BFD-62 | Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure" |
| P0BFE-62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure |
| P0BFF-1D | Drive Motor "A" Circuit Current Out of Range |
| P0C02-1D | Drive Motor "B" System Circuit Current Out of Range |
| P0C19-00 | Drive Motor "A" Execution Torque Performance |
| P0C1A-00 | Drive Motor "B" Execution Torque Performance |
| P0C50-13 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
| P0C50-16 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C50-17 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C50-1F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
| P0C55-13 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open |
| P0C55-16 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C55-17 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C55-1F | Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5A-13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
| P0C5A-16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5A-17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5A-1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
| P0C5F-13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open |
| P0C5F-16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5F-17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5F-1F | Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent |
| P0C79-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0C7A-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0D2D-16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
| P0D2D-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0D2D-1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
| P0DA3-16 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold |
| P0DA3-17 | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold |
| P0DA3-1F | Drive Motor "B" Inverter Voltage Sensor "A" Circuit Intermittent |
| P163E-94 | Drive Motor "A" Control Module Monitoring System Unexpected Operation |
| P163F-94 | Drive Motor "B" Control Module Monitoring System Performance Unexpected Operation |
| P19F9-1C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range |
| P1BFA-46 | Internal Control Module (EEPROM Resolver Learning Value) Calibration / Parameter Memory Failure |
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
| P1C2C-1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range |
| P1C5D-19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
| P1C5E-19 | Drive Motor "B" Inverter Circuit Current Above Threshold |
| P1C60-1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
| P1C62-1F | Generator Control Module Offset Power Circuit Intermittent |
| P1C63-1F | Drive Motor "B" Control Module Offset Power Circuit Intermittent |
| P1C65-1F | Generator Control Module Circuit Intermittent |
| P1C66-1F | Drive Motor "B" Control Module Circuit Intermittent |
| P1C67-1F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C68-1F | Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C6A-9F | Motor Shutdown Stuck Off |
| P1C6B-9F | Rear Motor Shutdown Stuck Off |
| P1CAD-49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
| P1CAE-49 | Drive Motor "B" Position Sensor Internal Electronic Failure |
| P1CB0-38 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
| P1CB1-38 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect |
| P1CB6-9E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
| P1CE2-11 | PCU Interlock Circuit Short to Ground |
| P1CE4-9E | Drive Motor "B" Inverter Voltage Sensor "A" Stuck On |
| P1F67-11 | Rear PCU Interlock Circuit Short to Ground |
| P2600-31 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P2600-96 | Coolant Pump "A" Control Circuit Component Internal Failure |
| P26F4-31 | Coolant Pump "C" Control Circuit No Signal |
| P26F4-96 | Coolant Pump "C" Control Circuit Component Internal Failure |
| P274A-11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A-15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A-1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A-1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P275A-11 | Transmission Fluid Temperature Sensor "D" Circuit Short to Ground |
| P275A-15 | Transmission Fluid Temperature Sensor "D" Circuit Short to Battery or Open |
| P275A-1C | Transmission Fluid Temperature Sensor "D" Circuit Voltage Out of Range |
| P275A-1F | Transmission Fluid Temperature Sensor "D" Circuit Intermittent |
| U0293-00 | Lost Communication with Hybrid/EV Powertrain Control Module |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U1150-87 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
| U115E-87 | Lost Communication with Drive Motor Control Module "B" (ch3) Missing Message |
| U1170-00 | Lost Communication with Brake System Control Module (Gear Shift Control Module "A") |
| U1170-08 | Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure |
| U11B3-08 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Bus Signal / Message Failure |
| U11B3-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |