Relay (For Gasoline Model)
RELAY (FOR GASOLINE MODEL)
| Standard Resistance (Injector Relay (INJ)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (Electronic Driver Unit Relay (D INJ)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (No. 1 Electronic Fuel Injection Main Relay (EFI-MAIN NO. 1)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (No. 2 Electronic Fuel Injection Main Relay (EFI-MAIN NO. 2)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (No. 3 Electronic Fuel Injection Main Relay (EFI-MAIN NO. 3)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (IGP Relay (IGP NO. 1)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |